Nova Grip load table

Load values are permissible ones per DIN 18800 - old

Clamping plate
a
b
Load
Support force
Tension force
of 8.8 screw
Torque
MoS2 lubricated
transferable
H-forces
u=0.1
for screw
[mm]
[mm]
P [kN]
B [kN]
A [kN]
Mv [Nm]
H [kN]
M 8
17.0
13.5
3.20
4.00
7.20
11.00
0.32
M10
See building supervision authority permit
M 12
See building supervision authority permit
M12 LA
30.0
16.0
4.00
7.50
11.50
18.10
0.40
M12 LAS
30.0
16.0
4.00
7.5
11.50
18.10
0.40
M 16
See building supervision authority permit
M 16 RF
46.0
26.0
9.50
16.80
26.30
58.50
0.95
M20
See building supervision authority permit
M24
See building supervision authority permit


Download building supervision authority permit as a PDF file.

 

 